tick: hrtimer-broadcast: Prevent endless restarting when broadcast device is unused

commit 38d23a6cc16c02f7b0c920266053f340b5601735 upstream.

The hrtimer callback in the hrtimer's tick broadcast code sometimes
incorrectly ends up scheduling events at the current tick causing the
kernel to hang servicing the same hrtimer forever. This typically
happens when a device is swapped out by
tick_install_broadcast_device(), which replaces the event handler with
clock_events_handle_noop() and sets the device mode to
CLOCK_EVT_MODE_UNUSED. If the timer is scheduled when this happens,
the next_event field will not be updated and the hrtimer ends up being
restarted at the current tick. To prevent this from happening, only
try to restart the hrtimer if the broadcast clock event device is in
one of the active modes and try to cancel the timer when entering the
CLOCK_EVT_MODE_UNUSED mode.

Change-Id: I6ee36e3dbc52428a6790a732b400ca1a9db9eacd
Signed-off-by: Andreas Sandberg <andreas.sandberg@arm.com>
Tested-by: Catalin Marinas <catalin.marinas@arm.com>
Acked-by: Mark Rutland <mark.rutland@arm.com>
Reviewed-by: Preeti U Murthy <preeti@linux.vnet.ibm.com>
Link: http://lkml.kernel.org/r/1429880765-5558-1-git-send-email-andreas.sandberg@arm.com
Signed-off-by: Thomas Gleixner <tglx@linutronix.de>
[bwh: Backported to 3.16 as dependency of commit b9023b91dd02
 "tick: broadcast-hrtimer: Fix a race in bc_set_next"]
Signed-off-by: Ben Hutchings <ben@decadent.org.uk>
This commit is contained in:
Andreas Sandberg 2015-04-24 13:06:05 +00:00 committed by syphyr
parent 39c00350fc
commit fb1dc39302
1 changed files with 7 additions and 3 deletions

View File

@ -22,6 +22,7 @@ static void bc_set_mode(enum clock_event_mode mode,
struct clock_event_device *bc)
{
switch (mode) {
case CLOCK_EVT_MODE_UNUSED:
case CLOCK_EVT_MODE_SHUTDOWN:
/*
* Note, we cannot cancel the timer here as we might
@ -101,10 +102,13 @@ static enum hrtimer_restart bc_handler(struct hrtimer *t)
{
ce_broadcast_hrtimer.event_handler(&ce_broadcast_hrtimer);
if (ce_broadcast_hrtimer.next_event.tv64 == KTIME_MAX)
switch (ce_broadcast_hrtimer.mode) {
case CLOCK_EVT_MODE_ONESHOT:
if (ce_broadcast_hrtimer.next_event.tv64 != KTIME_MAX)
return HRTIMER_RESTART;
default:
return HRTIMER_NORESTART;
return HRTIMER_RESTART;
}
}
void tick_setup_hrtimer_broadcast(void)